When a 100G SR4 link shows intermittent loss or power variance, the first step is to confirm the electrical‑optical topology. 100GBASE‑SR4 can be deployed as a native 4×25 Gb/s lane configuration or as a 100GBASE‑LR4/ER4 breakout (four 25 Gb/s SFP28s) from a QSFP28. Verify the module part number and the host port type: a QSFP28 with an MPO‑12×4‑type‑B connector is native SR4, while a QSFP28 that supports breakout will show a “BtoA” or “BtoC” configuration in the host BIOS/CLI and typically uses an MPO‑12×4‑type‑A or a dual‑LC breakout cable.

Next, check the MPO polarity. Most native SR4 modules follow the IEC‑61753‑1 polarity (fibre‑1 on pin‑1, fibre‑2 on pin‑2, etc.). A polarity mismatch will appear as a consistent 3‑4 dB loss on the affected lanes. Use a polarity‑checking fixture or a visual fault locator on each fibre to confirm alignment.

If the physical layer checks out, examine the DOM (Digital Optical Monitoring) values per lane. Typical Rx power for a clean SR4 link at 0 km is –5 dBm ± 3 dB; at 100 m it should be around –7 dBm. A lane reading below –12 dBm or showing >2 dB drift over a minute often indicates a bad fibre, dirty connector, or a failing transceiver. Compare the Tx power of the remote side – it should be within the –5 to –7 dBm range for a symmetric link.

Finally, validate the host error counters. A rising CRC error count without corresponding LOS/LOL flags usually points to a signal‑quality issue rather than a MAC problem.

What specific DOM parameter (Rx power, Tx bias, temperature) has proven most reliable in early detection of a failing SR4 lane in your deployments?